29 CFR 1926 · Construction · Subpart F

1926.152(e): Dispensing Flammable Liquids

By Black Belt Safety Editorial Team Official text as of October 15, 2026 Data updated October 19, 2026 3 min read

In plain words:

Areas where more than 5 gallons of flammable liquid is transferred at one time must be separated from other operations by 25 feet or by 1-hour fire-resistant construction, with spill control and ventilation keeping vapor at or below 10 percent of the lower flammable limit. Containers must be bonded for Category 1, 2 or 3 liquids, approved transfer methods must be used, air-pressure transfer is prohibited, and dispensers must be protected from collision.

Key takeaways

  • 1926.152(e) is part of OSHA's construction standards (29 CFR Part 1926, Subpart F).
  • OSHA cited it 46 times in the last 3 years, in 44 inspections, with $59,505 in current penalties.
  • Most citations: TN (15), VA (13), FL (6).
  • Related part: 1926.152(e)(4) (41 citations).
  • Free 5-minute toolbox talk for your crew below.
46citations, 3 years
$59,505current penalties
44inspections
0linked injury cases
In this article
  1. What this rule covers
  2. Official text
  3. Where and how often it was cited
  4. Free toolbox talk
  5. OSHA interpretation letters
  6. Related parts of this rule
  7. Get your crew competent
  8. Frequently asked questions
  9. About this page

What this rule covers

29 CFR 1926.152(e) ("Dispensing liquids") is one requirement inside 1926.152 Flammable liquids, an OSHA construction standard (Part 1926, Subpart F). It includes 5 sub-paragraphs. The official text below is copied word for word from the Electronic Code of Federal Regulations (eCFR). The numbers, injury cases and training on this page show how OSHA enforces it on real job sites.

Official text

(e) Dispensing liquids. 46 citations

(1) Areas in which flammable liquids are transferred at one time, in quantities greater than 5 gallons from one tank or container to another tank or container, shall be separated from other operations by 25-feet distance or by construction having a fire resistance of at least 1 hour. Drainage or other means shall be provided to control spills. Adequate natural or mechanical ventilation shall be provided to maintain the concentration of flammable vapor at or below 10 percent of the lower flammable limit.

(2) Transfer of Category 1, 2, or 3 flammable liquids from one container to another shall be done only when containers are electrically interconnected (bonded). Open (e)(2) 3 citations

(3) Flammable liquids shall be drawn from or transferred into vessels, containers, or tanks within a building or outside only through a closed piping system, from safety cans, by means of a device drawing through the top, or from a container, or portable tanks, by gravity or pump, through an approved self-closing valve. Transferring by means of air pressure on the container or portable tanks is prohibited. 2 citations

(4) The dispensing units shall be protected against collision damage. Open (e)(4) 41 citations

(5) Dispensing devices and nozzles for Category 1, 2, or 3 flammable liquids shall be of an approved type.

Source: eCFR, text current as of 2026-10-15. Read all of 1926.152.

Where and how often it was cited

YearCitations
20233
202414
202518
202611

Top states: TN (15), VA (13), FL (6), NJ (4), MD (2)

Largest penalties

EmployerLocationPenalty for this rule
US TANK PAINTING, INC.BAYVILLE, NJ$8,750
WHARTON-SMITH, INC.ORLANDO, FL$7,093
MORGAN-KELLER INC.NEWPORT NEWS, VA$6,292
TRIDENT CIVIL, INC.VIRGINIA BEACH, VA$3,672
IHC, LTDNEWPORT NEWS, VA$3,304

Free toolbox talk

A 5-minute crew talk on 1926.152(e), plus alerts when this rule changes. Free.




OSHA interpretation letters

Related parts of this rule

Get your crew competent

Trainers on Black Belt Safety: Marc Harvey, Dana Reyes

Trainers and suppliers: feature your business on this rule for $25/month.

Frequently asked questions

When does a dispensing area need separation?

When flammable liquids are transferred at one time in quantities greater than 5 gallons; it must be separated by 25 feet or by construction with at least a 1-hour fire resistance.

Must containers be bonded?

Yes. Category 1, 2 or 3 flammable liquids may be transferred only when containers are electrically interconnected (bonded).

Can air pressure be used to push liquid out of a container?

No. Transferring by air pressure on the container or portable tank is prohibited.

About this page

Sources

3-year window. Federal OSHA only; state-plan rules are not counted. Plain-language text is a summary, not legal advice; the official text controls. Black Belt Safety is not part of OSHA or the Department of Labor.

Written and reviewed by

Black Belt Safety Editorial Team

Site Safety Officer and Safety Professional

OSHA 30 · CPR · USACE CQM

Written and reviewed by the Black Belt Safety team. Every post is checked against the OSHA standard or agency source it cites.

Scroll to top