29 CFR 1926 · Construction · Subpart H

1926.251(e): Synthetic Web Slings

By Black Belt Safety Editorial Team Official text as of October 15, 2026 Data updated October 19, 2026 4 min read

In plain words:

Employers must have synthetic web slings marked with manufacturer, rated capacities by hitch and material type, and never exceed rated capacity. Webbing, fittings and stitching must meet stated requirements, slings must not be used around certain chemicals or above 180 °F for polyester and nylon or 200 °F for polypropylene, and damaged slings must be removed from service immediately.

Key takeaways

  • 1926.251(e) is part of OSHA's construction standards (29 CFR Part 1926, Subpart H).
  • OSHA cited it 39 times in the last 3 years, in 29 inspections, with $54,067 in current penalties.
  • 3 deaths are linked to inspections that cited this rule.
  • Most citations: TX (9), NY (7), OH (4).
  • Related part: 1926.251(e)(8) Removal from service (27 citations).
  • Free 5-minute toolbox talk for your crew below.
39citations, 3 years
$54,067current penalties
29inspections
3linked deaths
In this article
  1. What this rule covers
  2. Official text
  3. Injuries linked to this rule
  4. Where and how often it was cited
  5. Free toolbox talk
  6. OSHA interpretation letters
  7. Related parts of this rule
  8. Get your crew competent
  9. Frequently asked questions
  10. About this page

What this rule covers

29 CFR 1926.251(e) ("Synthetic webbing") is one requirement inside 1926.251 Rigging equipment for material handling, an OSHA construction standard (Part 1926, Subpart H). It includes 21 sub-paragraphs. The official text below is copied word for word from the Electronic Code of Federal Regulations (eCFR). The numbers, injury cases and training on this page show how OSHA enforces it on real job sites.

Official text

(e) Synthetic webbing (nylon, polyester, and polypropylene). 39 citations

(1) The employer shall have each synthetic web sling marked or coded to show: Open (e)(1) 6 citations

(i) Name or trademark of manufacturer. 1 citations

(ii) Rated capacities for the type of hitch. Open (e)(1)(ii) 3 citations

(iii) Type of material.

(2) Rated capacity shall not be exceeded.

(3) Webbing. Synthetic webbing shall be of uniform thickness and width and selvage edges shall not be split from the webbing's width.

(4) Fittings. Fittings shall be: Open (e)(4) 6 citations

(i) Of a minimum breaking strength equal to that of the sling; and

(ii) Free of all sharp edges that could in any way damage the webbing. Open (e)(4)(ii) 6 citations

(5) Attachment of end fittings to webbing and formation of eyes. Stitching shall be the only method used to attach end fittings to webbing and to form eyes. The thread shall be in an even pattern and contain a sufficient number of stitches to develop the full breaking strength of the sling.

(6) Environmental conditions. When synthetic web slings are used, the following precautions shall be taken:

(i) Nylon web slings shall not be used where fumes, vapors, sprays, mists or liquids of acids or phenolics are present.

(ii) Polyester and polypropylene web slings shall not be used where fumes, vapors, sprays, mists or liquids of caustics are present.

(iii) Web slings with aluminum fittings shall not be used where fumes, vapors, sprays, mists or liquids of caustics are present.

(7) Safe operating temperatures. Synthetic web slings of polyester and nylon shall not be used at temperatures in excess of 180 °F (82.2 °C). Polypropylene web slings shall not be used at temperatures in excess of 200 °F (93.33 °C).

(8) Removal from service. Synthetic web slings shall be immediately removed from service if any of the following conditions are present: Open (e)(8) 27 citations

(i) Acid or caustic burns;

(ii) Melting or charring of any part of the sling surface; Open (e)(8)(ii) 2 citations

(iii) Snags, punctures, tears or cuts; Open (e)(8)(iii) 17 citations

(iv) Broken or worn stitches; or Open (e)(8)(iv) 3 citations

(v) Distortion of fittings.

Source: eCFR, text current as of 2026-10-15. Read all of 1926.251.

Injuries linked to this rule

3 deaths are linked to inspections where OSHA cited 1926.251(e).

Employee is struck by falling steel guard and sustains fatal
2024-12-19 · Fatal · GEORGETOWN, TX

At 3:00 p.m. on December 19, 2024, Employee #1 was sitting on a trailer where heavy equipment was loaded onto the trailer bed. While seated, a steel guard from an excavation trencher slipped off a counterweight and struck him in the head. Employee #1 sustained…

See all 3 cases

Full case list with employer, penalty, filters and download is part of OSHA Data (Purple Belt).

Unlock with Purple Belt

Where and how often it was cited

YearCitations
20232
202411
202513
202613

Top states: TX (9), NY (7), OH (4), IL (3), MD (2)

Largest penalties

EmployerLocationPenalty for this rule
595 CONSTRUCTION LLCELBURN, IL$12,421
LEGENDARY CONSTRUCTION LLCLEMONT, IL$6,875
GLOBAL EARTHWORKS + UNDERGROUND LLCKANSAS CITY, MO$4,966
CUSTOM TRENCH INCGEORGETOWN, TX$4,966
BRADLEY FRAMING LLC.CINCINNATI, OH$4,965

Free toolbox talk

A 5-minute crew talk on 1926.251(e), plus alerts when this rule changes. Free.




OSHA interpretation letters

None exist. OSHA has not published a letter of interpretation for 1926.251(e).

Related parts of this rule

Get your crew competent

Trainers on Black Belt Safety: Marc Harvey, Dana Reyes

Trainers and suppliers: feature your business on this rule for $25/month.

Frequently asked questions

What must a synthetic web sling be marked with?

Name or trademark of manufacturer, rated capacities for the type of hitch, and type of material.

What temperature limits apply?

Polyester and nylon slings shall not be used above 180 °F (82.2 °C); polypropylene slings shall not be used above 200 °F (93.33 °C).

When can nylon web slings not be used?

Where fumes, vapors, sprays, mists or liquids of acids or phenolics are present.

About this page

Sources

3-year window. Federal OSHA only; state-plan rules are not counted. Plain-language text is a summary, not legal advice; the official text controls. Black Belt Safety is not part of OSHA or the Department of Labor.

Written and reviewed by

Black Belt Safety Editorial Team

Site Safety Officer and Safety Professional

OSHA 30 · CPR · USACE CQM

Written and reviewed by the Black Belt Safety team. Every post is checked against the OSHA standard or agency source it cites.

Scroll to top