1926.403(h): Label Disconnects and Circuits

By Black Belt Safety Editorial Team Official text as of October 15, 2026 Data updated October 19, 2026 3 min read

In plain words:

Each disconnecting means for motors and appliances, and each service, feeder and branch circuit at its disconnecting means or overcurrent device, must be legibly marked to show its purpose unless its location and arrangement make the purpose evident. Markings must be durable enough for the environment.

Key takeaways

  • 1926.403(h) is part of OSHA's construction standards (29 CFR Part 1926, Subpart K).
  • OSHA cited it 37 times in the last 3 years, in 37 inspections, with $62,121 in current penalties.
  • Most citations: VA (10), SC (10), KY (3).
  • Free 5-minute toolbox talk for your crew below.
37citations, 3 years
$62,121current penalties
37inspections
0linked injury cases
In this article
  1. What this rule covers
  2. Official text
  3. Where and how often it was cited
  4. Free toolbox talk
  5. OSHA interpretation letters
  6. Get your crew competent
  7. Frequently asked questions
  8. About this page

What this rule covers

29 CFR 1926.403(h) ("Identification of disconnecting means and circuits") is one requirement inside 1926.403 General requirements, an OSHA construction standard (Part 1926, Subpart K). The official text below is copied word for word from the Electronic Code of Federal Regulations (eCFR). The numbers, injury cases and training on this page show how OSHA enforces it on real job sites.

Official text

(h) Identification of disconnecting means and circuits. Each disconnecting means required by this subpart for motors and appliances shall be legibly marked to indicate its purpose, unless located and arranged so the purpose is evident. Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, shall be legibly marked to indicate its purpose, unless located and arranged so the purpose is evident. These markings shall be of sufficient durability to withstand the environment involved. 37 citations

Source: eCFR, text current as of 2026-10-15. Read all of 1926.403.

Where and how often it was cited

YearCitations
20233
202410
202515
20269

Top states: VA (10), SC (10), KY (3), PR (2), MD (2)

Largest penalties

EmployerLocationPenalty for this rule
FREEMAN & ASSOCIATES OF VIRGINIA INC.SUFFOLK, VA$16,100
68052 - LEE COMPANY OF TENNESSEE INCFRANKLIN, KY$7,000
LUXTERRA ELECTRICAL INCGLOUCESTER, VA$5,365
SEMINOLE MACHINE AND WELDING INC.LARGO, FL$4,286
VOLMAR CONSTRUCTION, INC.BRONX, NY$4,000

Free toolbox talk

A 5-minute crew talk on 1926.403(h), plus alerts when this rule changes. Free.




OSHA interpretation letters

Get your crew competent

Trainers on Black Belt Safety: Marc Harvey, Dana Reyes

Trainers and suppliers: feature your business on this rule for $25/month.

Frequently asked questions

Must every disconnect be labeled?

Each required disconnecting means must be legibly marked to indicate its purpose, unless located and arranged so the purpose is evident.

Where are circuits marked?

At the disconnecting means or overcurrent device.

How durable must labels be?

Of sufficient durability to withstand the environment involved.

About this page

Sources

3-year window. Federal OSHA only; state-plan rules are not counted. Plain-language text is a summary, not legal advice; the official text controls. Black Belt Safety is not part of OSHA or the Department of Labor.

Written and reviewed by

Black Belt Safety Editorial Team

Site Safety Officer and Safety Professional

OSHA 30 · CPR · USACE CQM

Written and reviewed by the Black Belt Safety team. Every post is checked against the OSHA standard or agency source it cites.

Scroll to top