29 CFR 1926 · Construction · Subpart O

1926.600(a)(6)(i): 10-Foot Crane Clearance for Lines 50 kV or Below

By Black Belt Safety Editorial Team Official text as of October 15, 2026 Data updated October 19, 2026 3 min read

In plain words:

For power lines rated 50 kV or below, the minimum clearance between the lines and any part of the crane or load must be 10 feet.

Key takeaways

  • 1926.600(a)(6)(i) is part of OSHA's construction standards (29 CFR Part 1926, Subpart O).
  • OSHA cited it 37 times in the last 3 years, in 37 inspections, with $427,936 in current penalties.
  • 3 deaths are linked to inspections that cited this rule.
  • Most citations: TX (10), MA (4), FL (3).
  • Related part: 1926.600(a) General requirements (111 citations).
  • Free 5-minute toolbox talk for your crew below.
37citations, 3 years
$427,936current penalties
37inspections
3linked deaths
In this article
  1. What this rule covers
  2. Official text
  3. Injuries linked to this rule
  4. Where and how often it was cited
  5. Free toolbox talk
  6. OSHA interpretation letters
  7. Related parts of this rule
  8. Get your crew competent
  9. Frequently asked questions
  10. About this page

What this rule covers

29 CFR 1926.600(a)(6)(i) is one requirement inside 1926.600 Equipment, an OSHA construction standard (Part 1926, Subpart O). The official text below is copied word for word from the Electronic Code of Federal Regulations (eCFR). The numbers, injury cases and training on this page show how OSHA enforces it on real job sites.

Official text

(i) For lines rated 50 kV or below, minimum clearance between the lines and any part of the crane or load shall be 10 feet; 37 citations

Source: eCFR, text current as of 2026-10-15. Read all of 1926.600.

Injuries linked to this rule

3 deaths are linked to inspections where OSHA cited 1926.600(a)(6)(i).

Employee dies after electrocuted, boom contacts power line
2025-01-15 · Fatal · BILOXI, MS

At 8:00 a.m. on January 15, 2025, Employee #1 was working for a concrete pumping service was pouring concrete with a pumping hose. The employee moved thehose boom which contacted a nearby overhead high voltage power line. Employee #1 was fatally injured.

See all 3 cases

Full case list with employer, penalty, filters and download is part of OSHA Data (Purple Belt).

Unlock with Purple Belt

Where and how often it was cited

YearCitations
20231
202411
202512
202613

Top states: TX (10), MA (4), FL (3), NY (2), MS (2)

Largest penalties

EmployerLocationPenalty for this rule
BLACK ROCK CONSTRUCTION MANAGEMENT, LLC.BRUCEVILLE, TX$145,652
A.D. PAOLINI LLCWINTHROP, MA$39,723
WALKER-HILL ENVIRONMENTAL, INC.OAKLAND, MS$16,550
CONCRETE PUMP PARTNERS LLCBILOXI, MS$16,550
REVOLI CONSTRUCTION CO., INCSOUTH YARMOUTH, MA$16,550

Free toolbox talk

A 5-minute crew talk on 1926.600(a)(6)(i), plus alerts when this rule changes. Free.




OSHA interpretation letters

None exist. OSHA has not published a letter of interpretation for 1926.600(a)(6)(i).

Related parts of this rule

Get your crew competent

Trainers on Black Belt Safety: Marc Harvey, Dana Reyes

Trainers and suppliers: feature your business on this rule for $25/month.

Frequently asked questions

How close can a crane get to a 50 kV line?

For lines rated 50 kV or below, minimum clearance between the lines and any part of the crane or load shall be 10 feet.

Does the clearance include the load?

Yes. It applies to any part of the crane or load.

Does this cover lines above 50 kV?

No. This paragraph covers lines rated 50 kV or below.

About this page

Sources

3-year window. Federal OSHA only; state-plan rules are not counted. Plain-language text is a summary, not legal advice; the official text controls. Black Belt Safety is not part of OSHA or the Department of Labor.

Written and reviewed by

Black Belt Safety Editorial Team

Site Safety Officer and Safety Professional

OSHA 30 · CPR · USACE CQM

Written and reviewed by the Black Belt Safety team. Every post is checked against the OSHA standard or agency source it cites.

Scroll to top