29 CFR 1926 · Construction · Subpart R

1926.760: Steel Erection Fall Protection

By Black Belt Safety Editorial Team Official text as of October 15, 2026 Data updated November 6, 2026 3 min read

In plain words:

Employers must protect steel erection workers on surfaces with an unprotected side or edge more than 15 feet above a lower level with guardrails, safety nets, personal fall arrest, positioning device or fall restraint systems. Perimeter safety cables are required on multi-story structures once decking is installed, and connectors and workers in controlled decking zones have their own rules.

Key takeaways

  • 1926.760 is part of OSHA's construction standards (29 CFR Part 1926, Subpart R).
  • OSHA cited it 357 times in the last 3 years, in 344 inspections, with $1,820,096 in current penalties.
  • 8 injury cases came from inspections that cited this rule, including 7 deaths.
  • Most citations: TX (36), PA (25), IL (23).
  • Most-cited part: 1926.760(a) General requirements (314 citations).
  • Free 5-minute toolbox talk for your crew below.

Get the free 5-minute toolbox talk on 1926.760 ↓

357citations, 3 years
$1,820,096current penalties
344inspections
8linked injury cases
In this article
  1. What this rule covers
  2. Official text
  3. Injuries linked to this rule
  4. Where and how often it was cited
  5. Free toolbox talk
  6. OSHA interpretation letters
  7. Most-cited parts of this rule
  8. Get your crew competent
  9. Frequently asked questions
  10. About this page

What this rule covers

29 CFR 1926.760, "Fall protection", is an OSHA construction standard (Part 1926, Subpart R). It has 23 numbered paragraphs. The official text below is copied word for word from the Electronic Code of Federal Regulations (eCFR). The numbers, injury cases and training on this page show how OSHA enforces it on real job sites.

Official text

Show the full text of 1926.760 (23 paragraphs)

(a) General requirements. Open (a) 314 citations

(1) Except as provided by paragraph (a)(3) of this section, each employee engaged in a steel erection activity who is on a walking/working surface with an unprotected side or edge more than 15 feet (4.6 m) above a lower level shall be protected from fall hazards by guardrail systems, safety net systems, personal fall arrest systems, positioning device systems or fall restraint systems. Open (a)(1) 314 citations

(2) Perimeter safety cables. On multi-story structures, perimeter safety cables shall be installed at the final interior and exterior perimeters of the floors as soon as the metal decking has been installed. Open (a)(2)

(3) Connectors and employees working in controlled decking zones shall be protected from fall hazards as provided in paragraphs (b) and (c) of this section, respectively. Open (a)(3)

(b) Connectors. Each connector shall: Open (b) 17 citations

(1) Be protected in accordance with paragraph (a)(1) of this section from fall hazards of more than two stories or 30 feet (9.1 m) above a lower level, whichever is less; Open (b)(1) 3 citations

(2) Have completed connector training in accordance with § 1926.761; and 2 citations

(3) Be provided, at heights over 15 and up to 30 feet above a lower level, with a personal fall arrest system, positioning device system or fall restraint system and wear the equipment necessary to be able to be tied off; or be provided with other means of protection from fall hazards in accordance with paragraph (a)(1) of this section. Open (b)(3) 11 citations

(c) Controlled Decking Zone (CDZ). A controlled decking zone may be established in that area of the structure over 15 and up to 30 feet above a lower level where metal decking is initially being installed and forms the leading edge of a work area. In each CDZ, the following shall apply: Open (c) 15 citations

(1) Each employee working at the leading edge in a CDZ shall be protected from fall hazards of more than two stories or 30 feet (9.1 m), whichever is less. 2 citations

(2) Access to a CDZ shall be limited to only those employees engaged in leading edge work. 1 citations

(3) The boundaries of a CDZ shall be designated and clearly marked. The CDZ shall not be more than 90 feet (27.4 m) wide and 90 (27.4 m) feet deep from any leading edge. The CDZ shall be marked by the use of control lines or the equivalent. Examples of acceptable procedures for demarcating CDZ's can be found in appendix D to this subpart. Open (c)(3) 8 citations

(4) Each employee working in a CDZ shall have completed CDZ training in accordance with § 1926.761. 2 citations

(5) Unsecured decking in a CDZ shall not exceed 3,000 square feet (914.4 m2). Open (c)(5)

(6) Safety deck attachments shall be performed in the CDZ from the leading edge back to the control line and shall have at least two attachments for each metal decking panel.

(7) Final deck attachments and installation of shear connectors shall not be performed in the CDZ. 2 citations

(d) Criteria for fall protection equipment. Open (d) 11 citations

(1) Guardrail systems, safety net systems, personal fall arrest systems, positioning device systems and their components shall conform to the criteria in § 1926.502 (see appendix G to this subpart). Open (d)(1) 9 citations

(2) Fall arrest system components shall be used in fall restraint systems and shall conform to the criteria in § 1926.502 (see appendix G). Either body belts or body harnesses shall be used in fall restraint systems. Open (d)(2) 2 citations

(3) Perimeter safety cables shall meet the criteria for guardrail systems in § 1926.502 (see appendix G). Open (d)(3)

(e) Custody of fall protection. Fall protection provided by the steel erector shall remain in the area where steel erection activity has been completed, to be used by other trades, only if the controlling contractor or its authorized representative: Open (e)

(1) Has directed the steel erector to leave the fall protection in place; and

(2) Has inspected and accepted control and responsibility of the fall protection prior to authorizing persons other than steel erectors to work in the area.

Source: eCFR, text current as of 2026-10-15.

See every company cited for this rule.

Export the list: 344 inspections cited 1926.760 in the last 3 years, with employer, location, penalty and date.

Purple Belt, $59/mo

Injuries linked to this rule

8 injury cases in the last 3 years came from inspections where OSHA cited 1926.760, including 7 deaths.

Employee falls from roof lacking fall protection and incurs
2025-01-03 · Fatal · HOUSTON, TX

At 12:00 p.m. on January 3, 2025, Employee #1 and coworkers had removed a large section of a metal roof to repair support structures, add insulation, and install new roofing material. After helping add a channel to the structure, Employee #1 climbed on the roof…

See all 8 cases

Full case list with employer, penalty, filters and download is part of OSHA Data (Purple Belt).

Unlock with Purple Belt

Where and how often it was cited

YearCitations
202312
2024138
2025111
202696

Top states: TX (36), PA (25), IL (23), MI (23), NY (22)

Largest penalties

EmployerLocationPenalty for this rule
JUAN CORDONAHARRISBURG, PA$116,518
EL DORADO STEEL ERECTORS, LLC.BIDDEFORD, ME$66,206
UNITED STRUCTURAL METAL FABRICATION, LLCCORPUS CHRISTI, TX$64,529
A.W. STILES CONTRACTORS INC.SMYRNA, NY$56,460
LEGEND FRAMING GROUP LLCCHAMPAIGN, IL$35,488

Free toolbox talk

A 5-minute crew talk on 1926.760, plus alerts when this rule changes. Free.




OSHA interpretation letters

None exist. OSHA has not published a letter of interpretation for 1926.760.

Most-cited parts of this rule

Get your crew competent

Trainers on Black Belt Safety: Marc Harvey

Trainers and suppliers: feature your business on this rule for $25/month.

Frequently asked questions

At what height do steel erectors need fall protection?

On a walking/working surface with an unprotected side or edge more than 15 feet (4.6 m) above a lower level, with special rules for connectors and controlled decking zones.

When must connectors be protected?

From fall hazards of more than two stories or 30 feet above a lower level, whichever is less, and they must complete connector training.

When must perimeter safety cables be installed?

On multi-story structures, at the final interior and exterior perimeters of floors as soon as metal decking has been installed.

About this page

Sources

3-year window. Federal OSHA only; state-plan rules are not counted. Plain-language text is a summary, not legal advice; the official text controls. Black Belt Safety is not part of OSHA or the Department of Labor.

Written and reviewed by

Black Belt Safety Editorial Team

Site Safety Officer and Safety Professional

OSHA 30 · CPR · USACE CQM

Written and reviewed by the Black Belt Safety team. Every post is checked against the OSHA standard or agency source it cites.

Scroll to top