1910.268(q)(2): Inspect Trees for Nearby Power Lines
Before anyone climbs, enters or works around a tree, the employee and the foreman or supervisor must closely inspect it to see whether a power conductor passes through it or within reach of a worker. If so, an electrical hazard exists unless the system operator/owner has deenergized the lines or installed protective equipment, and only qualified employees or trainees may do the work, with other rules on voltage, a second worker and minimum distances.
Key takeaways
- 1910.268(q)(2) is part of OSHA's general industry standards (29 CFR Part 1910, Subpart R).
- OSHA cited it 1 times in the last 3 years, in 1 inspections, with $7,000 in current penalties.
- 1 death is linked to inspections that cited this rule.
- Related part: 1910.268(q) Tree trimming (2 citations).
- Free 5-minute toolbox talk for your crew below.
Get the free 5-minute toolbox talk on 1910.268(q)(2) ↓
In this article
What this rule covers
29 CFR 1910.268(q)(2) ("Working in proximity to electrical hazards") is one requirement inside 1910.268 Telecommunications, an OSHA general industry standard (Part 1910, Subpart R). It includes 8 sub-paragraphs. The official text below is copied word for word from the Electronic Code of Federal Regulations (eCFR). The numbers, injury cases and training on this page show how OSHA enforces it on real job sites.
Official text
(2) Working in proximity to electrical hazards. 1 citations
(i) Employers shall ensure that a close inspection is made by the employee and by the foremen or supervisor in charge before climbing, entering, or working around any tree, to determine whether an electrical power conductor passes through the tree, or passes within reaching distance of an employee working in the tree. If any of these conditions exist either directly or indirectly, an electrical hazard shall be considered to exist unless the system operator/owner has caused the hazard to be removed by deenergizing the lines, or installing protective equipment. Open (q)(2)(i) 1 citations
(ii) Only qualified employees or trainees, familiar with the special techniques and hazards involved in line clearance, shall be permitted to perform the work if it is found that an electrical hazard exists.
(iii) During all tree working operations aloft where an electrical hazard of more than 750V exists, there shall be a second employee or trainee qualified in line clearance tree trimming within normal voice communication.
(iv) Where tree work is performed by employees qualified in line-clearance tree trimming and trainees qualified in line-clearance tree trimming, the clearances from energized conductors given in Table R-3 shall apply.
| Voltage range (phase to phase) (kilovolts) | Minimum working distance |
|---|---|
| 2.1 to 15.0 | 2 ft. 0 in. |
| 15.1 to 35.0 | 2 ft. 4 in. |
| 35.1 to 46.0 | 2 ft. 6 in. |
| 46.1 to 72.5 | 3 ft. 0 in. |
| 72.6 to 121.0 | 3 ft. 4 in. |
| 138.0 to 145.0 | 3 ft. 6 in. |
| 161.0 to 169.0 | 3 ft. 8 in. |
| 230.0 to 242.0 | 5 ft. 0 in. |
| 345.0 to 362.0 | 7 ft. 0 in. |
| 500.0 to 552.0 | 11 ft. 0 in. |
| 700.0 to 765.0 | 15 ft. 0 in. |
(v) Branches hanging on an energized conductor may only be removed using appropriately insulated equipment.
(vi) Rubber footwear, including lineman's overshoes, shall not be considered as providing any measure of safety from electrical hazards.
(vii) Ladders, platforms, and aerial devices, including insulated aerial devices, may not be brought in contact with an electrical conductor. Reliance shall not be placed on their dielectric capabilities.
(viii) When an aerial lift device contacts an electrical conductor, the truck supporting the aerial lift device shall be considered as energized.
Source: eCFR, text current as of 2026-10-15. Read all of 1910.268.
Export the list: 1 inspections cited 1910.268(q)(2) in the last 3 years, with employer, location, penalty and date.
Purple Belt, $59/moInjuries linked to this rule
1 death is linked to inspections where OSHA cited 1910.268(q)(2).
At 1:30 p.m. on August 3, 2024, an employee was in a vehicle-mounted boom lift, cutting tree branches that were adjacent to an electric/fiberoptic line pole. A portion of the tree was in contact with the energized electric line. As the employee was cutting a…
Where and how often it was cited
Free toolbox talk
A 5-minute crew talk on 1910.268(q)(2), plus alerts when this rule changes. Free.
OSHA interpretation letters
None exist. OSHA has not published a letter of interpretation for 1910.268(q)(2).
Related parts of this rule
- 1910.268(q) Tree trimming 2 citations
- 1910.268(q)(1)(ii) 1 citations
- 1910.268(q)(2)(i) 1 citations
- 1910.268(q)(1) General 1 citations
Get your crew competent
Trainers on Black Belt Safety: Marc Harvey
Trainers and suppliers: feature your business on this rule for $25/month.
Frequently asked questions
Who must inspect the tree?
The employee and the foreman or supervisor in charge, before climbing, entering or working around the tree.
When is a second qualified worker needed?
During tree work aloft where an electrical hazard of more than 750V exists, a second employee or trainee qualified in line clearance must be within normal voice communication.
Who may do the work if an electrical hazard exists?
Only qualified employees or trainees familiar with the special techniques and hazards of line clearance.
About this page
Sources
- 29 CFR 1910.268 (eCFR), text current as of 2026-10-15
- U.S. Department of Labor enforcement data: OSHA inspections, citations and accident records, copied nightly; data as of 2026-11-17