29 CFR 1910 · General Industry · Subpart R

1910.268(q): Tree Trimming Near Power Lines

By Black Belt Safety Editorial Team Official text as of October 15, 2026 Data updated November 17, 2026 6 min read

In plain words:

Employees pruning, trimming, removing or clearing trees from lines must treat all overhead and underground power conductors as energized with potentially fatal voltages and never touch them directly or indirectly. They must be instructed on direct and indirect contact, and the system operator/owner must be contacted before work near energized conductors.

Key takeaways

  • 1910.268(q) is part of OSHA's general industry standards (29 CFR Part 1910, Subpart R).
  • OSHA cited it 2 times in the last 3 years, in 1 inspections, with $14,000 in current penalties.
  • 1 death is linked to inspections that cited this rule.
  • Related part: 1910.268(q)(1)(ii) (1 citations).
  • Free 5-minute toolbox talk for your crew below.

Get the free 5-minute toolbox talk on 1910.268(q) ↓

2citations, 3 years
$14,000current penalties
1inspections
1linked deaths
In this article
  1. What this rule covers
  2. Official text
  3. Injuries linked to this rule
  4. Where and how often it was cited
  5. Free toolbox talk
  6. OSHA interpretation letters
  7. Related parts of this rule
  8. Get your crew competent
  9. Frequently asked questions
  10. About this page

What this rule covers

29 CFR 1910.268(q) ("Tree trimming") is one requirement inside 1910.268 Telecommunications, an OSHA general industry standard (Part 1910, Subpart R). It includes 20 sub-paragraphs. The official text below is copied word for word from the Electronic Code of Federal Regulations (eCFR). The numbers, injury cases and training on this page show how OSHA enforces it on real job sites.

Official text

(q) Tree trimming —electrical hazards— 2 citations

(1) General. Open (q)(1) 1 citations

(i) Employees engaged in pruning, trimming, removing, or clearing trees from lines shall be required to consider all overhead and underground electrical power conductors to be energized with potentially fatal voltages, never to be touched (contacted) either directly or indirectly.

(ii) Employees engaged in line-clearing operations shall be instructed that: Open (q)(1)(ii) 1 citations

(A) A direct contact is made when any part of the body touches or contacts an energized conductor, or other energized electrical fixture or apparatus.

(B) An indirect contact is made when any part of the body touches any object in contact with an energized electrical conductor, or other energized fixture or apparatus.

(C) An indirect contact can be made through conductive tools, tree branches, trucks, equipment, or other objects, or as a result of communications wires, cables, fences, or guy wires being accidentally energized.

(D) Electric shock will occur when an employee, by either direct or indirect contact with an energized conductor, energized tree limb, tool, equipment, or other object, provides a path for the flow of electricity to a grounded object or to the ground itself. Simultaneous contact with two energized conductors will also cause electric shock which may result in serious or fatal injury.

(iii) Before any work is performed in proximity to energized conductors, the system operator/owner of the energized conductors shall be contacted to ascertain if he knows of any hazards associated with the conductors which may not be readily apparent. This rule does not apply when operations are performed by or on behalf of, the system operator/owner.

(2) Working in proximity to electrical hazards. Open (q)(2) 1 citations

(i) Employers shall ensure that a close inspection is made by the employee and by the foremen or supervisor in charge before climbing, entering, or working around any tree, to determine whether an electrical power conductor passes through the tree, or passes within reaching distance of an employee working in the tree. If any of these conditions exist either directly or indirectly, an electrical hazard shall be considered to exist unless the system operator/owner has caused the hazard to be removed by deenergizing the lines, or installing protective equipment. Open (q)(2)(i) 1 citations

(ii) Only qualified employees or trainees, familiar with the special techniques and hazards involved in line clearance, shall be permitted to perform the work if it is found that an electrical hazard exists.

(iii) During all tree working operations aloft where an electrical hazard of more than 750V exists, there shall be a second employee or trainee qualified in line clearance tree trimming within normal voice communication.

(iv) Where tree work is performed by employees qualified in line-clearance tree trimming and trainees qualified in line-clearance tree trimming, the clearances from energized conductors given in Table R-3 shall apply.

Table R-3—Minimum Working Distances From Energized Conductors for Line-Clearance Tree Trimmers and Line-Clearance Tree-Trimmer Trainees

Voltage range (phase to phase) (kilovolts) Minimum working distance
2.1 to 15.0 2 ft. 0 in.
15.1 to 35.0 2 ft. 4 in.
35.1 to 46.0 2 ft. 6 in.
46.1 to 72.5 3 ft. 0 in.
72.6 to 121.0 3 ft. 4 in.
138.0 to 145.0 3 ft. 6 in.
161.0 to 169.0 3 ft. 8 in.
230.0 to 242.0 5 ft. 0 in.
345.0 to 362.0 7 ft. 0 in.
500.0 to 552.0 11 ft. 0 in.
700.0 to 765.0 15 ft. 0 in.

(v) Branches hanging on an energized conductor may only be removed using appropriately insulated equipment.

(vi) Rubber footwear, including lineman's overshoes, shall not be considered as providing any measure of safety from electrical hazards.

(vii) Ladders, platforms, and aerial devices, including insulated aerial devices, may not be brought in contact with an electrical conductor. Reliance shall not be placed on their dielectric capabilities.

(viii) When an aerial lift device contacts an electrical conductor, the truck supporting the aerial lift device shall be considered as energized.

(3) Storm work and emergency conditions.

(i) Since storm work and emergency conditions create special hazards, only authorized representatives of the electric utility system operator/owner and not telecommunication workers may perform tree work in these situations where energized electrical power conductors are involved.

(ii) When an emergency condition develops due to tree operations, work shall be suspended and the system operator/owner shall be notified immediately.

Source: eCFR, text current as of 2026-10-15. Read all of 1910.268.

See every company cited for this rule.

Export the list: 1 inspections cited 1910.268(q) in the last 3 years, with employer, location, penalty and date.

Purple Belt, $59/mo

Injuries linked to this rule

1 death is linked to inspections where OSHA cited 1910.268(q).

Employee is killed due to electric shock
2024-08-03 · Fatal · BATTLE CREEK, MI

At 1:30 p.m. on August 3, 2024, an employee was in a vehicle-mounted boom lift, cutting tree branches that were adjacent to an electric/fiberoptic line pole. A portion of the tree was in contact with the energized electric line. As the employee was cutting a…

Where and how often it was cited

Free toolbox talk

A 5-minute crew talk on 1910.268(q), plus alerts when this rule changes. Free.




OSHA interpretation letters

None exist. OSHA has not published a letter of interpretation for 1910.268(q).

Related parts of this rule

Get your crew competent

Trainers on Black Belt Safety: Marc Harvey

Trainers and suppliers: feature your business on this rule for $25/month.

Frequently asked questions

How must tree workers treat power lines?

As energized with potentially fatal voltages, never to be touched directly or indirectly.

What is indirect contact?

Touching any object in contact with an energized conductor, such as tools, branches, trucks or equipment.

Who must be contacted before work?

The system operator/owner of the energized conductors.

About this page

Sources

3-year window. Federal OSHA only; state-plan rules are not counted. Plain-language text is a summary, not legal advice; the official text controls. Black Belt Safety is not part of OSHA or the Department of Labor.

Written and reviewed by

Black Belt Safety Editorial Team

Site Safety Officer and Safety Professional

OSHA 30 · CPR · USACE CQM

Written and reviewed by the Black Belt Safety team. Every post is checked against the OSHA standard or agency source it cites.

Scroll to top