29 CFR 1926 · Construction · Subpart K

1926.404(b)(1)(iii)(C): Daily Visual Inspection of Cords and Tools

By Black Belt Safety Editorial Team Official text as of October 15, 2026 Data updated October 19, 2026 3 min read

In plain words:

Each cord set, plug, receptacle of cord sets, and cord-and-plug equipment must be visually inspected before each day's use for external defects like deformed or missing pins or insulation damage, and for signs of internal damage. Fixed cord sets and receptacles not exposed to damage are excepted, and damaged equipment must not be used until repaired.

Key takeaways

  • 1926.404(b)(1)(iii)(C) is part of OSHA's construction standards (29 CFR Part 1926, Subpart K).
  • OSHA cited it 42 times in the last 3 years, in 42 inspections, with $44,973 in current penalties.
  • Most citations: SC (7), VA (6), PR (5).
  • Related part: 1926.404(b) Branch circuits (138 citations).
  • Free 5-minute toolbox talk for your crew below.
42citations, 3 years
$44,973current penalties
42inspections
0linked injury cases
In this article
  1. What this rule covers
  2. Official text
  3. Where and how often it was cited
  4. Free toolbox talk
  5. OSHA interpretation letters
  6. Related parts of this rule
  7. Get your crew competent
  8. Frequently asked questions
  9. About this page

What this rule covers

29 CFR 1926.404(b)(1)(iii)(C) is one requirement inside 1926.404 Wiring design and protection, an OSHA construction standard (Part 1926, Subpart K). The official text below is copied word for word from the Electronic Code of Federal Regulations (eCFR). The numbers, injury cases and training on this page show how OSHA enforces it on real job sites.

Official text

(C) Each cord set, attachment cap, plug and receptacle of cord sets, and any equipment connected by cord and plug, except cord sets and receptacles which are fixed and not exposed to damage, shall be visually inspected before each day's use for external defects, such as deformed or missing pins or insulation damage, and for indications of possible internal damage. Equipment found damaged or defective shall not be used until repaired. 42 citations

Source: eCFR, text current as of 2026-10-15. Read all of 1926.404.

Where and how often it was cited

YearCitations
20231
202416
202518
20267

Top states: SC (7), VA (6), PR (5), TX (4), MD (3)

Largest penalties

EmployerLocationPenalty for this rule
POWER COMPONENT SYSTEMS INC.GREENWOOD, DE$5,745
CHETO'S ROOFINGKANSAS CITY, MO$4,839
D & R TANKPECOS, TX$4,000
TOMAS ATLAHUAFORNEY, TX$3,972
VIANE BRITOPROSPER, TX$3,405

Free toolbox talk

A 5-minute crew talk on 1926.404(b)(1)(iii)(C), plus alerts when this rule changes. Free.




OSHA interpretation letters

Related parts of this rule

Get your crew competent

Trainers on Black Belt Safety: Marc Harvey, Dana Reyes

Trainers and suppliers: feature your business on this rule for $25/month.

Frequently asked questions

How often must cords be inspected?

Before each day's use.

What defects are looked for?

External defects such as deformed or missing pins or insulation damage, and indications of possible internal damage.

Which items are excepted?

Cord sets and receptacles that are fixed and not exposed to damage.

About this page

Sources

3-year window. Federal OSHA only; state-plan rules are not counted. Plain-language text is a summary, not legal advice; the official text controls. Black Belt Safety is not part of OSHA or the Department of Labor.

Written and reviewed by

Black Belt Safety Editorial Team

Site Safety Officer and Safety Professional

OSHA 30 · CPR · USACE CQM

Written and reviewed by the Black Belt Safety team. Every post is checked against the OSHA standard or agency source it cites.