29 CFR 1926 · Construction · Subpart K

1926.405(g)(1): Permitted and Prohibited Uses of Flexible Cords

By Black Belt Safety Editorial Team Official text as of October 15, 2026 Data updated October 19, 2026 4 min read

In plain words:

Flexible cords and cables must suit the conditions and location and be used only for listed purposes such as pendants, fixtures, portable lamps or appliances, cranes and hoists, and frequently swapped stationary equipment. They must not replace fixed wiring, run through holes, doorways or windows except as permitted, attach to building surfaces, or be hidden behind walls, ceilings or floors.

Key takeaways

  • 1926.405(g)(1) is part of OSHA's construction standards (29 CFR Part 1926, Subpart K).
  • OSHA cited it 79 times in the last 3 years, in 76 inspections, with $38,293 in current penalties.
  • Most citations: PR (30), MD (17), VA (13).
  • Related part: 1926.405(g) Flexible cords and cables (476 citations).
  • Free 5-minute toolbox talk for your crew below.
79citations, 3 years
$38,293current penalties
76inspections
0linked injury cases
In this article
  1. What this rule covers
  2. Official text
  3. Where and how often it was cited
  4. Free toolbox talk
  5. OSHA interpretation letters
  6. Related parts of this rule
  7. Get your crew competent
  8. Frequently asked questions
  9. About this page

What this rule covers

29 CFR 1926.405(g)(1) ("Use of flexible cords and cables") is one requirement inside 1926.405 Wiring methods, components, and equipment for general use, an OSHA construction standard (Part 1926, Subpart K). It includes 16 sub-paragraphs. The official text below is copied word for word from the Electronic Code of Federal Regulations (eCFR). The numbers, injury cases and training on this page show how OSHA enforces it on real job sites.

Official text

(1) Use of flexible cords and cables — 79 citations

(i) Permitted uses. Flexible cords and cables shall be suitable for conditions of use and location. Flexible cords and cables shall be used only for: Open (g)(1)(i)

(A) Pendants; Open (g)(1)(i)(a)

(B) Wiring of fixtures; Open (g)(1)(i)(b)

(C) Connection of portable lamps or appliances; Open (g)(1)(i)(c)

(D) Elevator cables; Open (g)(1)(i)(d)

(E) Wiring of cranes and hoists; Open (g)(1)(i)(e)

(F) Connection of stationary equipment to facilitate their frequent interchange; Open (g)(1)(i)(f)

(G) Prevention of the transmission of noise or vibration; or Open (g)(1)(i)(g)

(H) Appliances where the fastening means and mechanical connections are designed to permit removal for maintenance and repair. Open (g)(1)(i)(h)

(ii) Attachment plugs for cords. If used as permitted in paragraphs (g)(1)(i)(C), (g)(1)(i)(F), or (g)(1)(i)(H) of this section, the flexible cord shall be equipped with an attachment plug and shall be energized from a receptacle outlet. 2 citations

(iii) Prohibited uses. Unless necessary for a use permitted in paragraph (g)(1)(i) of this section, flexible cords and cables shall not be used: Open (g)(1)(iii) 77 citations

(A) As a substitute for the fixed wiring of a structure; 6 citations

(B) Where run through holes in walls, ceilings, or floors; Open (g)(1)(iii)(b) 27 citations

(C) Where run through doorways, windows, or similar openings, except as permitted in paragraph (a)(2)(ii)(I) of this section; Open (g)(1)(iii)(c) 12 citations

(D) Where attached to building surfaces; or 3 citations

(E) Where concealed behind building walls, ceilings, or floors.

Source: eCFR, text current as of 2026-10-15. Read all of 1926.405.

Where and how often it was cited

YearCitations
202310
202416
202533
202620

Top states: PR (30), MD (17), VA (13), DE (3), IL (2)

Largest penalties

EmployerLocationPenalty for this rule
ENGLISH CONSTRUCTION COMPANY, INCORPORATEDFARMVILLE, VA$7,340
EUGENIO LARALAKESIDE MARBLEHEAD, OH$6,453
FLUSHING METAL WORK & SUPPLY INCNEW BRUNSWICK, NJ$4,839
SJ INVERSIONES Y DESARROLLOS LLCARECIBO, PR$2,550
ENVIRO-TAB, INC.MANATI, PR$2,550

Free toolbox talk

A 5-minute crew talk on 1926.405(g)(1), plus alerts when this rule changes. Free.




OSHA interpretation letters

Related parts of this rule

Get your crew competent

Trainers on Black Belt Safety: Marc Harvey, Dana Reyes

Trainers and suppliers: feature your business on this rule for $25/month.

Frequently asked questions

Can extension cords replace permanent wiring?

No. Unless necessary for a permitted use, flexible cords shall not be used as a substitute for fixed wiring.

Can cords be run through walls or doorways?

They shall not be run through holes in walls, ceilings or floors, or through doorways, windows or similar openings, except as permitted in (a)(2)(ii)(I).

When must a cord have a plug?

When used for portable lamps or appliances, frequently interchanged stationary equipment, or removable appliances, it must have an attachment plug and be energized from a receptacle.

About this page

Sources

3-year window. Federal OSHA only; state-plan rules are not counted. Plain-language text is a summary, not legal advice; the official text controls. Black Belt Safety is not part of OSHA or the Department of Labor.

Written and reviewed by

Black Belt Safety Editorial Team

Site Safety Officer and Safety Professional

OSHA 30 · CPR · USACE CQM

Written and reviewed by the Black Belt Safety team. Every post is checked against the OSHA standard or agency source it cites.

Scroll to top