1910.134(g): Proper Use of Respirators
Employers must not let workers with facial hair or other conditions that break the seal wear tight-fitting respirators, and must make sure glasses or other PPE do not interfere with the seal. Workers must do a user seal check each time they put one on, leave the area to wash, change filters or when they detect leakage, and employers must set procedures for IDLH atmospheres.
Key takeaways
- 1910.134(g) is part of OSHA's general industry standards (29 CFR Part 1910, Subpart I).
- OSHA cited it 679 times in the last 3 years, in 636 inspections, with $951,371 in current penalties.
- 3 deaths are linked to inspections that cited this rule.
- Most citations: TN (66), IL (47), MI (43).
- Related part: 1910.134(g)(1) Facepiece seal protection (641 citations).
- Free 5-minute toolbox talk for your crew below.
Get the free 5-minute toolbox talk on 1910.134(g) ↓
In this article
What this rule covers
29 CFR 1910.134(g) ("Use of respirators") is one requirement inside 1910.134 Respiratory protection, an OSHA general industry standard (Part 1910, Subpart I). It includes 27 sub-paragraphs. The official text below is copied word for word from the Electronic Code of Federal Regulations (eCFR). The numbers, injury cases and training on this page show how OSHA enforces it on real job sites.
Official text
(g) Use of respirators. This paragraph requires employers to establish and implement procedures for the proper use of respirators. These requirements include prohibiting conditions that may result in facepiece seal leakage, preventing employees from removing respirators in hazardous environments, taking actions to ensure continued effective respirator operation throughout the work shift, and establishing procedures for the use of respirators in IDLH atmospheres or in interior structural firefighting situations. 679 citations
(1) Facepiece seal protection. Open (g)(1) 641 citations
(i) The employer shall not permit respirators with tight-fitting facepieces to be worn by employees who have: Open (g)(1)(i) 606 citations
(A) Facial hair that comes between the sealing surface of the facepiece and the face or that interferes with valve function; or Open (g)(1)(i)(a) 524 citations
(B) Any condition that interferes with the face-to-facepiece seal or valve function. Open (g)(1)(i)(b) 23 citations
(ii) If an employee wears corrective glasses or goggles or other personal protective equipment, the employer shall ensure that such equipment is worn in a manner that does not interfere with the seal of the facepiece to the face of the user. Open (g)(1)(ii) 6 citations
(iii) For all tight-fitting respirators, the employer shall ensure that employees perform a user seal check each time they put on the respirator using the procedures in appendix B-1 or procedures recommended by the respirator manufacturer that the employer demonstrates are as effective as those in appendix B-1 of this section. Open (g)(1)(iii) 29 citations
(2) Continuing respirator effectiveness. 3 citations
(i) Appropriate surveillance shall be maintained of work area conditions and degree of employee exposure or stress. When there is a change in work area conditions or degree of employee exposure or stress that may affect respirator effectiveness, the employer shall reevaluate the continued effectiveness of the respirator. 2 citations
(ii) The employer shall ensure that employees leave the respirator use area: 1 citations
(A) To wash their faces and respirator facepieces as necessary to prevent eye or skin irritation associated with respirator use; or
(B) If they detect vapor or gas breakthrough, changes in breathing resistance, or leakage of the facepiece; or
(C) To replace the respirator or the filter, cartridge, or canister elements. 1 citations
(iii) If the employee detects vapor or gas breakthrough, changes in breathing resistance, or leakage of the facepiece, the employer must replace or repair the respirator before allowing the employee to return to the work area.
(3) Procedures for IDLH atmospheres. For all IDLH atmospheres, the employer shall ensure that: Open (g)(3) 14 citations
(i) One employee or, when needed, more than one employee is located outside the IDLH atmosphere; 2 citations
(ii) Visual, voice, or signal line communication is maintained between the employee(s) in the IDLH atmosphere and the employee(s) located outside the IDLH atmosphere; 4 citations
(iii) The employee(s) located outside the IDLH atmosphere are trained and equipped to provide effective emergency rescue; 2 citations
(iv) The employer or designee is notified before the employee(s) located outside the IDLH atmosphere enter the IDLH atmosphere to provide emergency rescue;
(v) The employer or designee authorized to do so by the employer, once notified, provides necessary assistance appropriate to the situation;
(vi) Employee(s) located outside the IDLH atmospheres are equipped with: 3 citations
(A) Pressure demand or other positive pressure SCBAs, or a pressure demand or other positive pressure supplied-air respirator with auxiliary SCBA; and either 2 citations
(B) Appropriate retrieval equipment for removing the employee(s) who enter(s) these hazardous atmospheres where retrieval equipment would contribute to the rescue of the employee(s) and would not increase the overall risk resulting from entry; or 1 citations
(C) Equivalent means for rescue where retrieval equipment is not required under paragraph (g)(3)(vi)(B).
(4) Procedures for interior structural firefighting. In addition to the requirements set forth under paragraph (g)(3), in interior structural fires, the employer shall ensure that: Open (g)(4) 19 citations
(i) At least two employees enter the IDLH atmosphere and remain in visual or voice contact with one another at all times; 7 citations
(ii) At least two employees are located outside the IDLH atmosphere; and 6 citations
(iii) All employees engaged in interior structural firefighting use SCBAs. 3 citations
One of the two individuals located outside the IDLH atmosphere may be assigned to an additional role, such as incident commander in charge of the emergency or safety officer, so long as this individual is able to perform assistance or rescue activities without jeopardizing the safety or health of any firefighter working at the incident.
Nothing in this section is meant to preclude firefighters from performing emergency rescue activities before an entire team has assembled.
Source: eCFR, text current as of 2026-10-15. Read all of 1910.134.
Export the list: 636 inspections cited 1910.134(g) in the last 3 years, with employer, location, penalty and date.
Purple Belt, $59/moInjuries linked to this rule
3 deaths are linked to inspections where OSHA cited 1910.134(g).
At 12:00 a.m. on August 29, 2024, Employee #1, a material handler at a steel fabrication facility, was taking his morning break in the breakroom. Upon returning to work after the break, he began complaining of trouble breathing andchest pain. He called 911, and a…
Full case list with employer, penalty, filters and download is part of OSHA Data (Purple Belt).
Unlock with Purple BeltWhere and how often it was cited
| Year | Citations |
|---|---|
| 2023 | 20 |
| 2024 | 288 |
| 2025 | 210 |
| 2026 | 161 |
Top states: TN (66), IL (47), MI (43), NC (40), NY (35)
Largest penalties
| Employer | Location | Penalty for this rule |
|---|---|---|
| CRASH CHAMPIONS COLLISION REPAIR | SAN ANTONIO, TX | $53,500 |
| STRATEGIC MATERIALS, INC | MIDLOTHIAN, TX | $42,000 |
| CRASH CHAMPIONS, LLC | ALLENTOWN, PA | $35,466 |
| CALIBER HOLDINGS LLC | LAS VEGAS, NV | $35,465 |
| CITY OF CHICAGO - FIRE DEPT. - BATTALION 11 | CHICAGO, IL | $30,000 |
Free toolbox talk
A 5-minute crew talk on 1910.134(g), plus alerts when this rule changes. Free.
OSHA interpretation letters
None exist. OSHA has not published a letter of interpretation for 1910.134(g).
Related parts of this rule
- 1910.134(g)(1) Facepiece seal protection 641 citations
- 1910.134(g)(1)(i) 606 citations
- 1910.134(g)(1)(i)(A) 524 citations
- 1910.134(g)(1)(iii) 29 citations
- 1910.134(g)(1)(i)(B) 23 citations
- 1910.134(g)(4) Procedures for interior structural firefighting 19 citations
- 1910.134(g)(3) Procedures for IDLH atmospheres 14 citations
- 1910.134(g)(1)(ii) 6 citations
Get your crew competent
Trainers on Black Belt Safety: Marc Harvey
Trainers and suppliers: feature your business on this rule for $25/month.
Frequently asked questions
Can I wear a tight-fitting respirator with a beard?
No, not if facial hair comes between the sealing surface and your face or interferes with valve function.
How often do I do a seal check?
Each time you put on a tight-fitting respirator.
What if I smell or taste the contaminant?
Leave the respirator use area. The employer must replace or repair the respirator before you go back.
About this page
Sources
- 29 CFR 1910.134 (eCFR), text current as of 2026-10-15
- U.S. Department of Labor enforcement data: OSHA inspections, citations and accident records, copied nightly; data as of 2026-11-17
3-year window. Federal OSHA only; state-plan rules are not counted. Plain-language text is a summary, not legal advice; the official text controls. Black Belt Safety is not part of OSHA or the Department of Labor.