29 CFR 1910 · General Industry · Subpart O

1910.212(a)(5): Fan Blade Guards

By Black Belt Safety Editorial Team Official text as of October 15, 2026 Data updated October 20, 2026 3 min read

In plain words:

When the outer edge of a fan's blades is less than seven feet above the floor or working level, employers must guard the blades with a guard having openings no larger than one-half inch.

Key takeaways

  • 1910.212(a)(5) is part of OSHA's general industry standards (29 CFR Part 1910, Subpart O).
  • OSHA cited it 121 times in the last 3 years, in 121 inspections, with $331,597 in current penalties.
  • 1 death is linked to inspections that cited this rule.
  • Most citations: NY (13), VA (12), TN (12).
  • Related part: 1910.212(a) Machine guarding (6,817 citations).
  • Free 5-minute toolbox talk for your crew below.
121citations, 3 years
$331,597current penalties
121inspections
1linked deaths
In this article
  1. What this rule covers
  2. Official text
  3. Injuries linked to this rule
  4. Where and how often it was cited
  5. Free toolbox talk
  6. OSHA interpretation letters
  7. Related parts of this rule
  8. Get your crew competent
  9. Frequently asked questions
  10. About this page

What this rule covers

29 CFR 1910.212(a)(5) ("Exposure of blades") is one requirement inside 1910.212 General requirements for all machines, an OSHA general industry standard (Part 1910, Subpart O). The official text below is copied word for word from the Electronic Code of Federal Regulations (eCFR). The numbers, injury cases and training on this page show how OSHA enforces it on real job sites.

Official text

(5) Exposure of blades. When the periphery of the blades of a fan is less than seven (7) feet above the floor or working level, the blades shall be guarded. The guard shall have openings no larger than one-half (1⁄2) inch. 121 citations

Source: eCFR, text current as of 2026-10-15. Read all of 1910.212.

Injuries linked to this rule

1 death is linked to inspections where OSHA cited 1910.212(a)(5).

Employee is killed when crushed by forklift
2023-11-21 · Fatal · HURON, SD

At 12:30 p.m. on November 21, 2023, an employee was using a forklift to load pallets onto a box truck. The employee attempted to back from the box truck to the dock, but the truck had rolled away, and the forklift fell to the ground.…

Where and how often it was cited

YearCitations
202312
202448
202542
202619

Top states: NY (13), VA (12), TN (12), OR (9), TX (7)

Largest penalties

EmployerLocationPenalty for this rule
68440 - PERISTYLE LLCHATTON, KY$70,000
PCP GROUP, LLCCLEARWATER, FL$16,147
THE GOODYEAR TIRE & RUBBER COMPANYDANVILLE, VA$13,415
SMITH-MIDLAND CORPORATIONMIDLAND, VA$13,415
J & S MANUFACTURING COMPANY, INCORPORATEDBRYANT, AR$11,292

Free toolbox talk

A 5-minute crew talk on 1910.212(a)(5), plus alerts when this rule changes. Free.




OSHA interpretation letters

Related parts of this rule

Get your crew competent

Trainers on Black Belt Safety: Marc Harvey, Dana Reyes

Trainers and suppliers: feature your business on this rule for $25/month.

Frequently asked questions

When do fan blades need a guard?

When the periphery of the blades is less than seven feet above the floor or working level.

How large can guard openings be?

No larger than one-half inch.

Do fans above seven feet need guards under this rule?

This paragraph applies when the blades are less than seven feet above the floor or working level.

About this page

Sources

3-year window. Federal OSHA only; state-plan rules are not counted. Plain-language text is a summary, not legal advice; the official text controls. Black Belt Safety is not part of OSHA or the Department of Labor.

Written and reviewed by

Black Belt Safety Editorial Team

Site Safety Officer and Safety Professional

OSHA 30 · CPR · USACE CQM

Written and reviewed by the Black Belt Safety team. Every post is checked against the OSHA standard or agency source it cites.

Scroll to top