29 CFR 1910 · General Industry · Subpart S

1910.305(a)(2)(v)(C): Keep Branch Circuit Conductors Off the Floor

By Black Belt Safety Editorial Team Official text as of October 15, 2026 Data updated October 20, 2026 2 min read

In plain words:

No branch circuit conductor in temporary wiring may be laid on the floor.

Key takeaways

  • 1910.305(a)(2)(v)(C) is part of OSHA's general industry standards (29 CFR Part 1910, Subpart S).
  • OSHA cited it 8 times in the last 3 years, in 8 inspections, with $25,268 in current penalties.
  • 1 death is linked to inspections that cited this rule.
  • Related part: 1910.305(a) Wiring methods (382 citations).
  • Free 5-minute toolbox talk for your crew below.
8citations, 3 years
$25,268current penalties
8inspections
1linked deaths
In this article
  1. What this rule covers
  2. Official text
  3. Injuries linked to this rule
  4. Where and how often it was cited
  5. Free toolbox talk
  6. OSHA interpretation letters
  7. Related parts of this rule
  8. Get your crew competent
  9. Frequently asked questions
  10. About this page

What this rule covers

29 CFR 1910.305(a)(2)(v)(C) is one requirement inside 1910.305 Wiring methods, components, and equipment for general use, an OSHA general industry standard (Part 1910, Subpart S). The official text below is copied word for word from the Electronic Code of Federal Regulations (eCFR). The numbers, injury cases and training on this page show how OSHA enforces it on real job sites.

Official text

(C) No branch-circuit conductor may be laid on the floor. 8 citations

Source: eCFR, text current as of 2026-10-15. Read all of 1910.305.

Injuries linked to this rule

1 death is linked to inspections where OSHA cited 1910.305(a)(2)(v)(C).

One employee is killed, another employee fractures both legs
2024-01-19 · Fatal · BAY SAINT LOUIS, MS

At 9:00 a.m. on January 19, 2024, two employees (Employee #1 and Employee #2) were setting up the site to create another stack of steel pipes (30 inches in diameter by 40 feet long, weighing over 2,000 pounds each.) The employees removed the chock block…

Where and how often it was cited

Free toolbox talk

A 5-minute crew talk on 1910.305(a)(2)(v)(C), plus alerts when this rule changes. Free.




OSHA interpretation letters

None exist. OSHA has not published a letter of interpretation for 1910.305(a)(2)(v)(C).

Related parts of this rule

Get your crew competent

Trainers on Black Belt Safety: Marc Harvey, Dana Reyes

Trainers and suppliers: feature your business on this rule for $25/month.

Frequently asked questions

Can temporary wiring lie on the floor?

No branch-circuit conductor may be laid on the floor.

Does this apply to temporary wiring?

Yes. It is part of the temporary wiring rules.

What should I do if I see wiring on the floor?

Report it so it can be moved.

About this page

Sources

3-year window. Federal OSHA only; state-plan rules are not counted. Plain-language text is a summary, not legal advice; the official text controls. Black Belt Safety is not part of OSHA or the Department of Labor.

Written and reviewed by

Black Belt Safety Editorial Team

Site Safety Officer and Safety Professional

OSHA 30 · CPR · USACE CQM

Written and reviewed by the Black Belt Safety team. Every post is checked against the OSHA standard or agency source it cites.

Scroll to top